3 inch tongue and groove roof decking

Insulation / Specifications - Lock-Deck Laminated DeckingBarrier. Rigid or Nail Base. Insulation. Built-up roofing. Membrane. Laminated. Wood decking. roof Slopes Over 4:12. roof Slopes Under 4:12. 7. Air film resistance, outside. 0.17. Asphalt shingles. 0.44. 3/8 plywood or OSB sheathing 0.47 ... (16 grit), resawn (cross band-saw tex- ture), or wire brushed. Nominal Sizes: 2x6, 2x8, 3x6, 3x8,. 4x6, 4x8, 5x6, and 5x8. Lengths: Random 6' to 16' or specified lengths up to 24'. End matched tongue- and-groove is standard. Square ends or.

Tongue and Groove Roof Decking - Galyon Timber20 Jul 2016 ... Most General Contractors, Architects, and Engineers we work with are accustomed to seeing tongue and groove roof decking as the structure that aesthetically enhances a cathedral ceiling. However, we ... We offer tongue and groove roof-decking in many different species, such as Southern Yellow Pine, Western Red Cedar, Douglas Fir, Spruce Pine Fir, and Ponderosa Pine. All of these options are ... Here are the standards for two-inch decking: Not less than 40% to ...

Products - Doubletree Forest Products: Cedar and Decking Product ...Doubletree Forest Products decking is your solid choice for a permanent roof deck with good insulating properties and a ready-to-finish interior ceiling. roof decking is especially suited for use with post and beam construction. Quality is important to us and it s not something that just happens. We took a hard look at existing products and set out to improve on them. We offer a unique pattern that makes for an easier installation, resulting in an improved final finish. It s not just our ...

Slate Roof: 3/4" plywood deck vs. 3/4" solid tongue and groove pine ...4 Jul 2013 ... http://www.verroneroofing.net/education-center Chris Verrone, a slate roofing expert, discusses the difference between a 3/4" plywood deck vs. a 3/4" solid t...

Lock-Deck Laminated Decking - Goodfellow Inc.glue-laminated decking. The decking is used for ceilings and roofs, as well as for balconies, mezzanines and floors. With Lock-Deck, extraordinary designs can be created for homes, churches, offices and other structures. Lock-Deck is ... 3. Product Description. Patterns. Standard Vee, Square Edge,. Channel, Bull Nose. Center laminations are offset and machined to form a tongue and groove on both the edges (center match) and the ends (end match). Lengths. Random 6' to 16', ...

Tongue & Groove Decking - SI Storey Lumber Companyrules. This decking can also be pressure treated with Osmose NatureWood ACQ preservative to provide longer life when exposed to conditions which can accelerate decay and permit insect attack. Specifications. roof decking is southern pine as manufactured by S.I. Storey Lumber Co.,. Inc. It is nominal 2 x 6, 3 x 6, or 4 x 6 in #1 or #2 grade and kiln dried. Maximum moisture content is 19% for 2 x 6, 3 x 6 and. 4 x 6. decking is machined to a single or double tongue and groove EVIS ...

Standard for Tongue-and-Groove Roof Decking - American Institute ...Standard for tongue-and-groove roof decking, AITC 112-93 7. 2 ft minimum end joint spacing. Figure 7. Controlled Random Layup. (Two inch decking). Three and Four inch decking. There shall be a minimum distance of 4 ft between end joints in adjacent courses. 4 ft rhinirrhum end joint spacing. Figure 8, Controlled Random Layup. (Three & Four inch decking). Cantilever Spans With Controlled Random Layup. When the overhang does not exceed 1-. 1/2 ft, 2 ft and 3 ft for nominal ...

Engineered Wood Construction Guide1-3/32. 60. 48. . . . 290 160 100. 65. 40 a. Includes APA RATED SHEATHING/CEILING DECK. b. Applies to APA RATED SHEATHING and APA RATED STURD-I-FLOOR panels 24 inches or wider applied over two or more spans. c. tongue-and-groove edges, panel edge clips (one midway* between each support, except two equally spaced between supports 48 inches on center or greater), lumber blocking, or other. For low slope roofs, see Table 35. *No established tolerance.

Chapter 23 - International Code Council2304.3.3 Shrinkage.Wood walls and bearing partitions shall not support more than two floors and a roof unless an analysis satisfactory to the building official shows that shrinkage of the wood framing will not have adverse effects on the struc- ..... 2304.8.4 Two-inch sawn tongue-and-groove decking. 2304.8.4.1 General. Two-inch (51 mm) decking shall have a maximum moisture content of 15 percent. Deck- ing shall be machined with a single tongue-and-groove pattern. Each deck ...

Shelton Lock-Deck Laminated Decking - APA The Engineered ...12 Apr 2017 ... AITC 112-13 Standard for tongue-and-groove Hea

Tougue and Groove Roof Decking - American Wood Counciltongue and groove roof decking. Two-Span Continuous. All pieces are supported on three supports. All end joints occur in line on every other support (Figure 6). Controlled Random Layup. This arrangement is applicable to 4 or more supports. (3 or more spans). With less than 4 supports, a special pattern requiring specified lengths must be used. Joints in the same general line (within 6 inches of being in line each way) shall be separated by at least two intervening courses.

The Long and Short of Wood Roof Systems - WoodWorks30 Sep 2014 ... 9/30/2014. 12. Lumber decking. See IBC 2012 2304.8. American Wood Council's Wood. Construction Data No. 2 tongue and Grove roof decking. Lumber decking. Code Acceptance for 2, 3 and 4 inch thick tongue. & groove Lumber decking per IBC 2012 2304.8. 2x6 T&C Doug Fir. Photo Bear Creek Lumber. 3x6 Double T&G Pine. Photo Southern Wood Specialities ...

Product Details