compression load for composite deck

Strain and Stress Distributions in Composite Deck ... - Scholars' MineDegtyarev, Vitaliy V., "Strain and Stress Distributions in composite deck Slabs: A Numerical Study" (2014). International Specialty ... have proved to be effective in predicting load-deflection responses of composite deck slabs. The study showed that the strain and stress distributions are greatly affected by concrete cracking and slip between the deck and the concrete. The study provides information ... span length; fy is yield strength of deck steel; f'c is concrete compressive strength.

Attachment N. Design Example with Normal Weight Concrete Beam ...compression - Permanent loads (beam): 2.925 ksi. Cast-in-Place deck Slab. compression - Total loads (deck): 2.400 ksi. Concrete Type: NWC. compression - Total loads (beam): 3.900 ksi. Concrete Unit Weight: 0.150 kcf. Tension: -0.484 ksi ... 5.8 ksi. 28-day Strength: 6.5 ksi. Calculated Stresses at Service (at midspan). Modulus of Elasticity, Ec: 4,888 ksi. Effective Haunch Depth: 0.50 in. Stress Limit Stress. Limit Stress Limit. loads. Non-composite DL: 1.721 kip/ft. composite DL:.

Load Capacities of Steel and Concrete Composite Bridge Deck Slab ...18 Oct 2017 ... Four SCC slab specimens with haunch were tested to evaluate the load capacities of positive and negative moment regions of the proposed composite bridge deck slabs. Failure .... In order to evaluate the effects of both compressive strength and tensile strength of concrete on the behavior of SCC bridge deck slab, the PMC composite was carefully designed in order that PMC has smaller concrete compressive strength but larger concrete tensile strength than OC.

Design Example on Composite Steel Deck Floor ... - Scholars' Minemeans the bottom of the deck is in compression. The AISI properties given assumed a minimum yield strength of 33 ksi, with a base steel thickness of 0.042 inches. The last two properties given are "m" the slope, and "k" the y intercept of the straight line developed from laboratory tests con- ducted in accordance with Chapter 3 of the criteria. The first four steps calculate the dead load and the maximum deflection of the steel deck as a form. The maximum deflection can- not exceed 3/4 ...

Seismic design of composite metal deck and concrete - nzseebeam design for members collecting lateral loads in composite floor systems has gone largely undocumented. This discussion paper presents a suggested ... Seismic Design of composite Steel deck and Concrete-filled Diaphragms and was produced by the. NEHRP Consultants Joint Venture, a partnership of the Applied .... Be aware of component forces introduced when a compression load changes direction and ensure that slab reinforcement is put in to resist any tension forces ...

Transcend a - DeckingPart 1 General. 1.1 Section Includes. A. composite decking ( Transcend and Enhance) ... Tread of Stairs: Concentrated load: 750 lbf/sq.ft., and 1/8 max. deflection with a concentrated load of 300 lbf ... ASTM D1761. 558 lbs/in. Fungus Resistance. ASTM D1413. Rating - no decay. Termite Resistance. AWPAE1-72. Rating = 9.6. Ultimate (Typical)Values * Design Values. compression Parallel. ASTM D198. 1588 psi. 540 psi. compression Perpendicular ASTM D143. 1437 psi.

deck products - Bushwick Metalsdeck. PRODUCTS. ROOF deck. composite deck. NON-composite deck. CELLULAR deck. composite CELLULAR deck. DEEP ROOF deck associate member .... load tables are calculated using section properties based on the steel design thickness shown in the Steel deck Institute (SDI) design man

Composite Steel Floor Deck - Slabs - Steel Deck Institute1. Concrete placed on steel deck shall conform to ACI 318, Chapters 3, 4 and 5, except as modified by Sections 2.1.D.2 and 2.1.D.3. 2. The specified concrete compressive strength shall not be less than 3000 psi (21. MPa). The maximum compressive strength used to calculate the strength of the composite deck-slab shall not exceed 6000 psi (42 MPa). User Note: load tables and labeled fire resistant rated assemblies may require concrete compressive strengths in excess of 3000 psi.

Bending and Shear Experimental Tests and Numerical Analysis of ...23 Nov 2016 ... However, theoretical prediction of composite slabs is very difficult because it depends on many variables, such as the geometry of steel deck and embossments. m-k tests determine relative displacement between the steel sheet and the concrete when shear stress is applied to the composite slab. In this test, a cyclic load is applied in order to take into account the whole life cycle of the composite slabs before collapse. The application of this cyclic load is required to ...

Canam - Steel Deck Diaphragm (Canada)This Canam steel deck publication presents diaphragm load tables based on the North American Specification for the. Design of Cold-formed ..... shear between compression and tension chords. Less connectors for ... for roof deck and 600 mm (24 in.) for composite floor deck with smaller spacing required for steel deck used as a diaphragm. It may be necessary to specify additional connections along the lateral load resisting line to transfer the lateral force to the VLLR. In this case ...

Canam - Steel Deck Catalogue (Canada)loads. Proper analysis should be done by an engineer to verify the effects of those concentrated loads on the deck or composite deck-slab. for example: The wheel load of rolling equipment on the steel deck during roofing material installation. ..... P-3615 & P-3606 composite. 11. The table is based on concrete density of 2 400 kg/m3 and mini- mum compressive resistance (f'c) equal to 20 MPa at 28 days. During construction, the steel deck must support itself, the concrete and.

Design of Partially or Fully Composite Beams with Ribbed Metal ...(Fig. 1). The floor beams generally are designed for only gravity loads imposed by the floor as simply supported composite beams with the slab essentially in compression over the full span of the beam. The beam normally is of a standard rolled, wide-flange shape designed to interact compositely with the concrete floor slab by means of shear studs placed in metal decking troughs. In such a metal deck composite beam system, the ribs or corrugations generally run perpendicular to the ...

Concrete Cracking in New Bridge Decks and Overlays - Wisconsin ...experimental results indicate that the decks' 28-day unconfined compression strength of the concrete was much higher than the design target. Furthermore, the ..... concrete deck. Even if the deck is not cracked due to concrete shrinkage, the combination of traffic load and concrete shrinkage appears capable of ..... shows a plot of an assumed temperature gradient throughout a composite deck and girder (Saadeghvaziri and Hadidi 2002). As shown, there is a steeper gradient in ...